Masibus FIB MAS-AI-08-D_R0F_0114_Field Interface Board 8 Analog Input
Input Output Control Method
8 Channel Analog Input Module MAS-AI-08-D
Storage Temperature
60 Degree
Basic Error Limit Voltage Ranges
NA
Bridge Supply Voltage Exc
NA
Current Consumption From Backplane Bus
.05W
Destruction Limit Current Inputs
Not Applicable
Input Current
As per field
Input current ranges
As per field
Input Voltage Max
As per field
Maximum High Level Output Current
As per field
Maximum Low Level Output Current
As per field
Output current
As per field
Country of Origin
Made in India
Masibus Analog Input Field Interface Board has 8 channels that accepts various types of current/voltage signals and converts them to isolated current/voltage signals. It is compact universal DIN rail mounted with labeled input and output connections. Each channel zero and span calibration is adjustable by multi-turn potentiometers. It can be used as PLC/DCS Interfacing Module. It is compatible with both 2 wire and 4 wire transmitters and has built-in transmitter power supply to power 2 Wire field transmitters. Offers excellent accuracy and stability for reliable operation in hostile environments and offers full 3 port isolation between input, output and power supply.
Features
3-Way isolation for analog signals
Wide Input / Output Range
+/- 0.1% accuracy across span drift 0.1% per year
LED indication for signal over / under
24VDC @25mA Transmitter power supply
Output option with D-type or PCB terminal
Front calibration facility via Multiturn Trimpot
Universal DIN Rail Mounting
Applications
Field interface device
Isolation of field signals
Translation of signals
Field Interface for PLC/DCS/SCADA systems
Impedance matching of transmitters and receiver instruments
Eliminate Ground Loop problems
Protect Expensive control systems against Field Faults
Masibus Analog Output Field Interface Board has 8 channels that accepts various types of current/voltage signals and converts them to isolated current/voltage signals. It is compact universal DIN rail mounted with labeled input and output connections. Independent zero & span adjustment for each channel is possible.
Offers excellent accuracy and stability for reliable operation in hostile environments and offers full 3 port isolation between input, output and power supply.
Features
3-Way isolation for analog signals
Wide Input / Output Range
+/- 0.1% accuracy across span
drift 0.1% per year
LED indication for signal over / under
Input option with D-type or PCB terminal
Front calibration facility via Multiturn Trimpot
Universal DIN Rail Mounting
Applications
Field interface device
Isolation of field signals
Translation of signals
Field Interface for PLC/DCS/SCADA systems
Protect expensive control systems against field faults
Masibus Linearized Thermocouple RTD Field Interface module have 8 nos of independent Thermocouple or Pt-100 RTD (3W) input channels. All 8 channels have factory set either Current or Voltage Output signal. Optionally offered Windows based User friendly mTRAN configuration software allows user to configure each channel for different type of TC/RTD input. Field interface module has channel wise open sensor indication that allows user to identify channel wise faults.
The interface modiules are built using the latest Technology to deliver high performance in Accuracy, Resolution, Stability and Isolation.
Linearized RTD / TC Field Interface module have Zero/Span adjustments, sensor break detection/protection, Reverse output and Reverse Polarity protection features.
Software techniques like polynomial Linearization gives Linearized output to deliver high accuracy. High level of isolation between Input and output prevents ground loop errors and protects costly measurement and control systems under fault conditions in harsh industrial conditions.
Features
Universal input (RTD, thermocouple)
1.5 KV AC RMS Isolation between Input, Output and Power
Linearized Output
Fast Response time: <500 ms
Fully Programmable for Input type & Range
Optional Windows mTRAN software for Configuration, Calibration & Monitoring
Reverse polarity protection
Direct/Reverse output settable
Sensor break detection
Universal DIN Rail Mounting
Applications
Reduce cost/channel for RTD / TC input
Eliminate Ground Loop problems
Protect Expensive control systems against field faults
Isolate and Translate Field Signals
Eliminate Common Mode Voltages
Industrial process control, Factory automation, SCADA and DAS
Masibus 16-Channel Digital Field Interface Module is designed to interface variety of digital signals between many automation and control products like PLC/DCS/RTU. This module is available in compact DIN rail mounting and has labeled input and output connections for easy installation, operation and maintenance
This module provides up to 1.5KVAC galvanic isolation between input, output and supply for rugged, stable and reliable operations. It has 24VDC auxiliary power supply. These modules are validated to be used even in harsh environment up to 55??C ambient temperature and 95% relative humidity (Non-Condensing).
Features
AC / DC Voltage Input Range
Output Open Collector (Source or Sink)
Signal Healthy Indication for each Channel
Output Option with FRC or D-type
Universal DIN Rail Mounting
Applications
Translate and Isolate AC/DC field voltages to 24V signals
Protect expensive control systems against field faults
Digital field interface for PLC/DCS/SCADA systems
Output compatible with source/sink system side modules
Masibus Modbus Relay Field Interface Module MAS-RS-RL is compact universal DIN rail mount with RS485 communication. It is available in 4 or 8 channel option. Output can be expanded up to 31 expansion modules per controller. Slave ID selection can be done using DIP switch.
Features
Available in 4 and 8 channel
1.5KV AC isolation between primary to secondary terminals ( primary indicates power and output terminals, secondary indicates communication O/P)
LED indication for Rx, Tx and relay status
Communication:Rs485 (2 Wire)-MODBUS RTU Protocol
Universal DIN Rail Mounting
Applications
Translate and Isolate AC/DC field voltages to 24V signals
Protect expensive control systems against field faults
Digital field interface for PLC/DCS/SCADA systems
Output compatible with source/sink system side modules